– Flow meter for fixed installation
– Different outputs for process connection
– For fixed installation
– For pipe diameters 25 … 1200 mm / 1 in … 47.2 in
| Measuring range | ± 0.03 … ± 5 m / s (± 0.09 … ± 16 ft / s) |
| Measurement accuracy | ± 1% of the measured value |
| Repeatability | 0.2% |
| Pipe diameter | 25 … 1200 mm (1 … 48 in) |
| Analog output | 0/4 … 20 mA (maximum load 750 Ω) |
| Pulse output | 0 … 9999 Hz OCT |
| (Frequency limits are adjustable) | |
| Relay output | 1 A at 125V AC, 2 A at 30V DC |
| Maximum frequency 1 Hz | |
| Communication interface | RS232 & RS485 |
| Power supply | 10 … 36V DC |
| Power consumption | 1 A |
| Display | LCD, 256 x 128 pixels, with backlight |
| Ambient conditions base | -40 … 60°C / -40 … 140°F 0 … 99% RH non-condensing |
| Ambient conditions sensor | -40 … 80°C / -40 … 176° F 0 … 99% RH non-condensing |
| Housing material base | PC / ABS |
| Protection class base | IP 65 |
| Protection class sensor | IP 68 |
| Cable length | 9 m / 30 ft |
| Dimensions | 16 x 23 x 28 cm / 6.3 x 9.1 x 11″ |
| Weight | 3.2 kg / 7.1 lbs |